New energy vehicle
主页 > ENGLISH > PRODUCTS > New energy vehicle >
NVR6V-100BN
NVR6V-100B download
1. CCC and RoHS compliant;
2. Contacts sealed in ceramic capsules and inert gas;
3. Contacts protected against contamination. e.g oxidation and corrosion;
4. Magnet arc blowout;
5. Up to 900VDC Cutoff;
6. Compact and lightweight;
一、 Product Names and Type Rules
  NVR6V - 100 B / 800 - 12 - H C 5 ( )
Product Type NVR6V Ceramic                        
Load Current 100:100A                    
Series Indicator BB Series                  
Load Voltage 800:800V              
Coil Voltage 12:12VDC          
Contact Form H: 1 Form A of Main Contact      
Coil Terminal Form C:Connector    
Load Terminal Form 5:Internal Thread  
Special Code Customer's special requirements


二、 Coil Data
@23 ℃
Rated Voltage Vd.c. Coil Type
Operate Voltage
Vd.c.

Release Voltage
Vd.c.

Coil Resistance Ω(@23℃)


Coil Power
(Approx.) W
12
Single Coil
≤9 ≥1.2 24×(1±7%) 6
 
三、Contact Data

Main Contact
Contact Form 1 Form A
Contact Material Copper Alloy
Contact Resistance ≤0.4mΩ (@100A)
Contact Rating Current 100A(@35mm2 Copper bar)
Max. Breaking Current 1000A/450Vd.c.(1 op)
Max. Switching Voltage 800Vd.c.
Min. Applicable Load 6Vd.c./1A
Operate Time ≤30ms
Bounce Time ≤5ms
Release Time ≤10ms
Current Endurance 100A    Cont.
150A   2h
200A   10min
400A   30s
600A   10s
900A   4s
 



Current Endurance Curve                                                                                                                                                                                                                                                                                                             
 Notes:
1) 
The ambient temperature is 85℃, and the cross-sectional area of the copper bar is ≥35mm². Supply rated voltage to coil;
2) 
The upper limit of the function temperature is 130℃, which is suitable for long-time working; and the upper limit of the safe temperature is 180℃, which is suitable for short-time working; If the temperature exceeds 180℃,the contactor may fail;
3) 
The contactor’s contacts may be repelled when the current is greater than 2000A, if the fuse does not blow
in time, the contactor may catch fire or explode.


四、 Endurance

Electrical Life(Resistivity)
Making:     14.5Vd.c./100A    5×104(ops)
450Vd.c./100A    1×104(ops)
Breaking:    800Vd.c./100A    1500(ops)
450Vd.c./100A    4000(ops)
Mechanical Life 200,000(ops)
 
 Notes:
1) 
Electrical Life tests are conducted in room temperature. Supply rated voltage to coil. On/off ratio is 0.6s:5.4s;
2) 
Mechanical Life tests are conducted in room temperature. Supply rated voltage to coil. On/off ratio is 0.5s:0.5s.
五、Other Properties

Insulation Resistance

Between Open Contacts
 Before Test:
≥1000MΩ(@1000Vd.c.)
After Test:
≥50MΩ (@1000Vd.c.)

Between Closed Contact and Coil
Before Test:
≥1000MΩ(@1000Vd.c.)
After Test:
≥50MΩ(@1000Vd.c.)

Dielectric Strength

Between Open Contacts
(Leak Current≤1 mA)
Before Test:
≥3000Va.c.,(50/60 Hz, 1min)
After Test:
≥2250Va.c.,(50/60 Hz, 1min)
Between Closed Contact and Coil (Leak Current≤1 mA) Before Test:
≥2500Va.c.,(50/60 Hz, 1min)
After Test:
≥1875Va.c.,(50/60 Hz, 1min)
Mechanical Shock-Destructive 50G
Mechanical Shock-Functional 20G
Vibration 10-500Hz,5G
 


六、Configuration
1.  Product Model:NVR6V-100B/800-xx-HC5
1.1.  Outline Dimensions
 
 
1.2. Wiring Diagram

No polarity on the load and coil

1.3. Product Weight
 
Specification Weight
12V Approx.260g
24V Approx.260g

 Notes:
1) All unspecified tolerance please refer to the following table:
Dimension(mm) <10 10~50 >50
Tolerance(mm) ±0.3 ±0.5 ±0.8
2)  Recommended connector:
Yazaki 7283-1020
THB 0435317
3) The default product is shipped without connector harness,screws,washers,spring washers and other installation accessories.

七、Application Condition
Application Condition Standards Test Condition Operating Condition Storage Condition
Temperature 23 ℃±5 ℃ -40℃~+85℃ -40℃~+85℃
Humidity 25%~75%RH 5%~85%RH 5%~85%RH
Altitude ≤2000m ≤4000m ≤4000m
Direction  Same as Installation Direction Vertical
Forward Packing
 
Notes:
1) 
Since the fixed contact of this product is made of pure copper, if the storage time is longer, the oxidation degree of the contact surface should be checked before use. If oxidation discoloration has occurred, the surface of the contact should be polished to remove the oxide layer before use.The storage environment should avoid condensation and icing.
2) 
If the storage time exceeds 3 months, the parameters of the contactor should be tested again before use.
3) 
When the altitude exceeds 2000m, it should be used with reduced capacity according to the requirements of IEC 60947-1.

八、 Others
1. Please avoid foreign bodies, grease or corrosive liquids in the terminal, otherwise it will lead to abnormal heating at contact terminals.
2. Please avoid installation in strong magnetic field (around the transformers, the magnet) and the heating objects nearby.
3. In order to prevent loosening, please use the washer when installing the relay. Please use the M5 screws to install relay, screw locking torque within 3 N·m~4N·m; Damage may occur when it is beyond the range.
4. Please pay attention to the thickness of copper bars and the value of the torque. If it goes beyond the recommended values in the below table , it will cause thread slide or installation is not tight. To avoid short circuit or fire,it’s not suggest fix two copper bus bar at same side.

Screw on the load terminal

Recommended thickness of copper bus bar
Recommended hole dimension of copper bus bar Recommended Flatness of copper bus bar
Torque
M6 2~3mm Ф6.0mm~
Ф6.5 mm
0.1 6N·m~8N·m
 
5. The rating load of contact is resistive load. Please assure the surge absorption device together with inductive load when using the L/R≥1 ms inductive load (L Load),otherwise it may lead to the decrease of electrical endurance and defective switch.
6. The relay contacts are sealed and filled with gas. When the contact temperature changes, there is internal gas penetrating characteristic.Neputune relays are forbidden to be used at the temperature beyond our suggestion -40 ℃~85 ℃ for long time.
7. In principle, please do not use it when the relay has fallen down.
8. Neptune products are all RoHS2.0 compliant.
9. Neptune reserves the right to change the product. Customers should confirm the version of the specification before purchasing the product.
10. Please contact Neptune Electric (Kunshan) Co., Ltd for more information or support.

上一篇:NVR6V-M300ST